H. pylori Test Reagent
Cat. No.: KAI-240
Type: Reagent
Method: Immunoturbidimetric
Format: Liquid
Linearity: 3 - 100 U/mL
Sample: Serum, Plasma


KIT COMPOSITION
R1:   1 X 60 mL buffer
R2:   1 X 12 mL antibody

Tests / Kit:   300 (Hitachi 917)
(Can Vary Based On Analyzer Model)
    
KAI-240
Click Image To Enlarge       

Click here for an example package insert.

Click here for the Safety Data Sheets (SDS):
Reagent-1 (R-1)
Reagent-2 (R-2)

Click here for information about recommended calibrators and controls.


INTENDED USE
For the qualitative determination of anti-Helicobacter pylori antibodies in human serum and plasma by immunoturbidimteric assay on automated clinical chemistry analyzers.
FOR RESEARCH USE ONLY IN THE U.S.
NOT FOR USE IN DIAGNOSTIC PROCEDURES IN THE U.S.

REAGENT PREPARATION
The reagents are ready to use.  They do not need to be reconstituted.

STORAGE AND HANDLING
All reagents should be stored refrigerated (2-8°C).  Return all reagents to 2-8°C promptly after use.  Unopened reagents can be used for one year from the date of manufacture, as indicated by the expiration date on the package and bottle labels.  Opened reagents can be used for 8 weeks if stored at 2-8°C.

INTERFERENCE
Bilirubin :     No interference up to 30 mg/dL
Hemoglobin :     No interference up to 500 mg/dL
Lipemia :     No interference up to 5% Intra-fat